Ballycatter.fr. Marché industriel - Trouvez des fournisseurs d'équipements et de services
Secure Login System PHP
Secure Login System PHP
    ×
  • Toutes nos catégories
  • Construction
  • Marin
  • Sous-Marin
  • Équipement de processus
  • Transport
  • Reconditionnement de puits
  • Complétions de puits
  • Forage
  • Service Clients
  • Les partenaires
Inverter and Charger Combination

Inverter and Charger Combination

MultiPlus Inverter/Chargers


Aussi connu sous le nom:

Power System

Buy

Made to Order

Product

New

ASME

Land Freight

Titre:

Inverter and Charger Combination

Numéro de modèle:

2 kVA and 3 kVA

Disponibilité:

Made to Order

Délai de livraison (semaines):

4 weeks

Choose

AMS Hydro à Vancouver

Pour des informations sur les produits ou services, la personnalisation ou d'autres questions


Spécifications

Type de transaction

Buy

Condition

New

Poids

25 lbs

Lieu

Canada

Type d'entreprise

Product Provider

Assurance qualité

ASME

Prix

Request for Quote Based on specifications

Matériel

Steel

Marque

Victron

Livraison

Land Freight

Nota

The MultiPlus is a powerful true sine wave inverter and a sophisticated battery charger.

Voir plus de produits de cette entreprise

plus de produits de l'entreprise >

À propos de cet article

  • PowerControl - Dealing with limited generator, shore side or grid power
  • PowerAssist - Boosting the capacity of shore or generator power
  • Split phase options
  • Three phase capability

Description

Multifunctional, with intelligent power management The MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the MultiPlus has several advanced features, as outlined below. Two AC Outputs The main output has no-break functionality. The MultiPlus takes over the supply to the connected loads in the event of a grid failure or when shore-/generator power is disconnected. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on the input of the MultiPlus. Loads that should not discharge the battery, like a water heater for example, can be connected to this output (second output available on models rated at 3kVA and more). Virtually unlimited power thanks to parallel operation Up to six Multis can operate in parallel to achieve higher power output. Six 24/3000/70 units, for example, provide 15kW / 18kVA output power with 420 Amps of charging capacity. Three phase capability In addition to parallel connection, three units can be configured for three-phase output. But that’s not all: with three strings of six parallel units a 45 kW / 54 kVA three phase inverter and 1260 A charger can be built. Split phase options Two units can be stacked to provide 120-0-120 V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30 kW / 36 kVA of split phase power. Alternatively, a split phase AC source can be obtained by connecting our autotransformer (see data sheet on www.victronenergy.com) to a ‘European’ inverter programmed to supply 240 V / 60 Hz. PowerControl - Dealing with limited generator, shore side or grid power The MultiPlus is a very powerful battery charger. It will therefore draw a lot of current from the generator or shore side supply (nearly 20 A per 3 kVA MultiPlus at 120 VAC). With the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded. PowerAssist - Boosting the capacity of shore or generator power This feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery. Four stage adaptive charger and dual bank battery charging The main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery. System configuring has never been easier After installation, the MultiPlus is ready to go. If settings have to be changed, this can be done in a matter of minutes with a DIP switch setting procedure. Even parallel and 3-phase operation can be programmed with DIP switches: no computer needed! Alternatively, VE.Net can be used instead of the DIP switches. And sophisticated software (VE.Bus Quick Configure and VE.Bus System Configurator) is available to configure several new, advanced, features. *information from manufacturer catalogue


Logistique

Livraison:

Sea freight - Land freight | International shipment of items may be subject to customs processing and additional charges.

Situé:

Canada


Vous aimerez peut-être aussi

Voir plus >

Envoyer un message

Message:

To: supplier

Untitled Document